<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-23 16-53-44
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 52 dBuV VOLTAGE
Pilot RDS Phase Difference
6.4 kHz 3.8 kHz -8 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 72 kHz 10098 15,9041
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
4,9 dBr 7,37 dBr 8,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 16:53, 23.04.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (52 dBuV) Max at: 72 kHz MIN: 11 kHz % above 76 kHz: 15,9041 Acquired: 2025/04/23 16:52:41 Total samples: 10098 Equivalent time: 0:08:24 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 8,2 dBr MIN: 4,9 dBr AVE: 7,37 dBr % above 10,2 dBr: 0,0 Last value: 6,2 dBr (2025/04/23 16:52:40) Station: 96.90 MHz, signal: 4/5 (52 dBuV) 16:46 16:47 16:48 16:49 16:50 16:51 16:52 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality